Rotel RSX-1058 Owner's Manual Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 92
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
36
RSX-1058 Surround Sound Receiver
4. If no station is located for the desired con-
tent type, the tuner will return to the last
previously tuned station.
5. Cancel the PTY function by pressing any
other button.
NOTE: If the currently tuned station is broad-
casting PTY data, a PTY indicator lights in the
front-panel display.
TP Button
Searches for an RDS station broadcasting
traffic information programming:
1. Press the TP button. The tuner attempts to
find an RDS station broadcasting the traf-
fic programming. If a station is found, a
TP indicator lights in the front-panel dis-
play.
2. If no station is located, the tuner will re-
turn to the last previously tuned station.
3. Cancel the TP function by pressing any
other button.
TA Button
Searches for an RDS station broadcasting
special traffic announcements:
1. Press the TA button. The tuner will attempt
to find an RDS station broadcasting traf-
fic announcements.
2. If no station is located, the tuner will re-
turn to the last previously tuned station.
3. Cancel the TA function by pressing any
other button.
Zone 24 Operation
The RSX-1058 provides Zone 2–4 multi-room
capability, allowing you to enjoy music and
operate the system from up to three addi-
tional rooms or zones. From these remote
locations, you can select a source compo-
nent (independent from the source playing
in the main room), adjust the volume level
in the remote zone, and operate the source
components.
To use the Zone 2–4 capability, you need
additional components: a pair of speakers
installed in the remote zone, an amplifier
to drive them, an optional TV monitor for
video signals, and a third-party IR repeat-
er system.
Zones 24 can be controlled from the main
room using RSX-1058’s front-panel SEL or
remote control REC button. Operation from
the remote zone or zones requires the instal-
lation of an infrared repeater system (Xan-
tech, Niles, etc.) which relays infrared remote
control commands from Zone 2, 3 or 4 to
the specific ZONE REM IN connector on the
back of the RSX-1058.
Several points to keep in mind about the
Zone 24 function:
There are two options for output level, se-
lectable from the OSD configuration menu.
VARIABLE output provides full adjustment
of the volume level. FIXED output disables
the Zone 2, 3 or 4 volume control with the
output permanently set to a specified level.
This might be useful for sending a line level
signal to a preamp or integrated amp with
its own volume control or to a distribution
amplifier with multiple volume controls.
The RR-1060 remote control supplied with
the RSX-1058 will operate Zone 2, 3 or
4 if used with a repeater system from the
remote zone. It can also be programmed
to operate Rotel source components via
the RSX-1058’s IR OUT jack.
Any source component connected to the
RSX-1058’s analog inputs can be sent
to the Zone 2, 3 or 4 outputs. ZONE 2,
ZONE 3 and ZONE 4 operate indepen-
dently of the main room. You can select
a different source or adjust Zone 2, 3 or
4 volume from each zone without affect-
ing the MAIN outputs in any way.
Avoid sending the same infrared com-
mand to the RSX-1058 front-panel sen-
sor and a Zone 2, 3 or 4 repeater at the
same time. This means that Zones 2, 3
or 4 must be in a different room from
the RSX-1058.
Zone 2–4 Power On/Off
Once master power is applied to the unit
by pressing the rear panel POWER switch
button, the RSX-1058 provides independent
power on/off operation for all zones. Press-
ing the remote control ON/OFF buttons in
the main room activates or deactivates the
RSX-1058 in the main room only and has no
effect on Zone 2, 3 or 4. Conversely, acti-
vating or deactivating Zone 2, 3 or 4 has
no effect on the main listening room. How-
ever, placing the rear panel master POWER
switch in the OFF position completely shuts
off the unit, for all zones.
NOTE: For proper power on and off operation
with Zones 2–4, the RSX-1058’s power mode
should be set to the factory default STANDBY
setting or to the DIRECT setting using the Other
Options menu described in the Setup section
of this manual.
Controlling Zones 24
from the Main Room
You can control Zones 24 from the main room
using front-panel or remote control buttons
to activate or deactivate Zones 2–4, change
input sources, and adjust the volume. Con-
trolling Zone 2, 3 or 4 from the main room is
accomplished by pressing the SEL button on
the front panel or REC button on the remote
two or more times, putting the RSX-1058 in
Zone 2, 3 or 4 control mode temporarily.
When Zone 2, 3 or 4 status is displayed,
the OSD and/or front-panel displays show
the current source selection and volume in
that zone for ten seconds, during which time
you can use the front panel VOLUME control
and INPUT buttons to change the ZONE 2,
3 or 4 settings.
To turn Zone 2, 3 or 4 on or off:
1. Press the front panel SEL or remote REC
button repeatedly until the desired zone
status appears in the OSD and front panel
displays.
2. Within 10 seconds, press the front panel
or remote ZONE button to toggle the se-
lected Zone on or off.
3. Following 10 seconds with no commands,
the RSX-1058 reverts to normal opera-
tion.
To change the Zone 2, 3 or 4 input
source:
1. Press the front panel SEL or remote REC
button repeatedly until the desired zone
status appears in the OSD and front panel
displays.
2. Within 10 seconds, press one of the IN-
PUT buttons to select a new source for the
selected zone. The name of the selected
source appears in the display. Instead of
Page view 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 91 92

Comments to this Manuals

No comments