RX-1050 AM/FM Stereo Receiver
Specifications
Audio
Continuous Amplifier Power
100 watts/channel
(20–20k Hz, <0.05% THD, 8 ohms)
Total Harmonic Distortion
<0.05% at rated power
Intermodulation Distortion (60 Hz:7 kHz)
<0.05% at rated power
Frequency Response
Line Level: 10 Hz - 70 kHz, ±3 dB
Phono: 20 Hz - 20 kHz, ±1 dB
Signal to Noise Ratio (IHF “A” weighted)
Line Level: 92 dB
Phono: 74 dB
Input Overload
Line Inputs: 5 V
Phono Inputs: >120 mV
Preamplifier Output Voltage
1.0 V (160 mV Input)
Input Sensitivity/Impedance
Line Level: 160 mV/47 kohms
Phono: 2.5 mV/47 kohms
Tone Controls (Bass/Treble)
±8 dB at 100 Hz/10 kHz
Video
Frequency Response
3 Hz-10 MHz, ± 3 dB
Signal to Noise Ratio
45 dB
Input Impedance
75 ohms
Output Impedance
75 ohms
Output Level
1 volt
FM Tuner
Usable Sensitivity
14.2 dBf
50dB Quieting Sensitivity
20.2 dBf (mono)
45.3 dBf (stereo)
Signal to Noise Ratio (at 65 dBf)
70 dBf (mono)
65 dBf (stereo)
Harmonic Distortion (at 65 dBf)
0.3% (mono)
0.5% (stereo)
Frequency Response
30 Hz-14 kHz, ±1.5 dB
Capture Ratio
2.0 dB
Alternate Channel Selectivity
47 dB (±400 kHz)
Spurious Response Ratio
80 dB
Image Response Ratio
65 dB
IF Response Ratio
80 dB
AM Suppression Ratio
52 dB
Stereo Separation (100Hz/1 kHz/10 kHz):
40 dB/45 dB/35 dB
Output level
1.3 V
Antenna Input
75 ohms unbalanced
AM Tuner
Sensitivity
500 µV/m
Selectivity
25 dB
Image Response Ratio
35 dB
Signal to Noise Ratio
40 dB
Output level
250 mV
Antenna Input
Loop Antenna
General
Power Consumption
300 watts
Power Requirements (AC)
115 volts, 60 Hz (USA version)
230 volts, 50 Hz (European version)
Weight
10.3 Kg/22.7 lb.
Dimensions (W x H x D)
432 x 121 x 359 mm
17" x 4
3/4" x 141/8"
Front Panel Height
(feet removed/for rack mount)
176 mm / 7"
All specifications are accurate at the time of
printing.
Rotel reserves the right to make improvements
without notice.
Rotel and the Rotel HiFi logo are registered
trademarks of The Rotel Co, Ltd., Tokyo, Japan.
IR OUT Jacks
See Figure 6.
The IR OUT 1 & 2 jacks send IR signals re-
ceived at the ZONE REM IN jack or the EX-
TERNAL REM IN jack to an infrared emitter
placed in front of a source component or to
Rotel CD players, cassette decks, or tuners with
a compatible rear panel IR connector.
This output is used to allow IR signals from Zone
2 to be sent to the source components, or to
pass along IR signals from a remote in the main
room when the sensors on the source compo-
nents are blocked by installation in a cabinet.
See your authorized Rotel dealer for information
on IR repeater systems.
NOTE
: The EXT REM IN jack located to the
right of these jacks is for use with an external
IR sensor duplicating the front-panel IR sen-
sor and located in the primary zone. It should
not be used for ZONE 2 IR connections.
Protection Circuit
A thermal protection circuit protects the am-
plifier against potential damage in the event
of extreme or faulty operating conditions. Unlike
many designs, the RX-1050’s protection cir-
cuit is independent of the audio signal and
has no impact on sonic performance. Instead,
the protection circuit monitors the temperature
of the output devices and shuts down the am-
plifier if temperatures exceed safe limits.
Should a faulty condition arise, the amplifier
will stop playing. If this happens, turn the
amplifier off, let it cool down for several min-
utes, and attempt to identify and correct the
problem. When you turn the amplifier back
on, the protection circuit will automatically reset.