English
NOTE: By default, the RR-AT97 operates
the Rotel RT-1080/RT-961/RT-955 tuners.
The remote can be reprogrammed to oper-
ate the RT-940AX tuner. This programming
only needs to be done once:
To program for the RT-940AX:
press
the ON button and the 2 button simultane-
ously.
To program for the RT-1080/
RT-961/RT-955:
press the ON button
and the 1 button simultaneously.
Troubleshooting
Most difficulties in audio systems are the result
of incorrect connections, or improper control
settings. If you encounter problems, isolate the
area of the difficulty, check the control settings,
determine the cause of the fault and make the
necessary changes. If you are unable to get
sound from the RC-1082, refer to the sugges
-
tions for the following conditions:
Standby Power Indicator Is
Not Lit
The Standby Power Indicator should be lit
whenever the RC-1082 is plugged into the
wall power outlet. If it does not light, test the
power outlet with another electrical device,
such as a lamp. Be sure the power outlet be
-
ing used is not controlled by a switch that has
been turned off.
Fuse Replacement
If another electrical device works when plugged
into the power outlet, and the Standby Indicator
still will not light when the RC-1082 is plugged
into the wall outlet, it indicates that the internal
power fuse may have blown. If you believe this
has happened, contact your authorized Rotel
dealer to get the fuse replaced.
No Sound
Check the signal source to see if it is functioning
properly. Make sure the cables from the signal
source to the RC-1082 inputs are connected
properly. Be sure the Listening Selector is set
to the proper input. Check the power ampli
-
fier for power and proper operation. Check
all the wiring between the RC-1082 and the
power amplifier, and the power amplifier
and speakers.
Specifications
Total Harmonic Distortion (20Hz-20kHz) < 0.004%
Intermodulation Distortion (60 Hz : 7 kHz, 4:1) < 0.004% at 1V output
Input Sensitivity / Impedance
Phono - MC 250 µV / 100 ohms
Phono - MM 2.5 mV / 47 kOhms
Line Level 150 mV / 220 kOhms
Phono Overload (MC/MM) 16 mV / 160 mV
Output Sensitivity / Impedance 1 V/ 100 Ohms
Frequency Response
Phono Input 20Hz-20kHz, ± 0.2dB
Line Level Input 4Hz-100kHz, ± 0.5dB
Signal to Noise Ratio (IHF “A” weighted)
Phono - MC/MM 70 dB/75 dB
Line Level 100 dB
Power Requirements
USA Version 120 Volts, 60 Hz
European Version 230 Volt, 50 Hz
Power Consumption 15 Watts
Standby Power Consumption 2.5 Watts
Dimensions (W x H x D) 432 x 92 x 344 mm
17 x 3
5
/8 x 13
9
/16
Weight (net) 7.5 kg, 16.53 lbs.
All specifications are accurate at the time of printing.